  "schema_version": "0.2.0",
  "generated_at": "2026-07-14T14:13:38Z",
  "records": [
    {
      "schema_version": "0.1.0",
      "id": "tariff-nj-bpu-rockland-electric-sc7-high-voltage",
      "state": "NJ",
      "commission_id": "commission-nj-bpu",
      "docket_number": "ER25060374",
      "related_case_id": "case-nj-bpu-er25060374",
      "title": "Rockland Electric SC7 High Voltage Distribution service",
      "slug": "rockland-electric-sc7-high-voltage",
      "tariff_name": "Service Classification No. 7 — High Voltage Distribution",
      "customer_scope": "data_center_and_large_load",
      "utility_id": "utility-rockland-electric",
      "parent_company_id": "company-consolidated-edison",
      "status": "effective",
      "filed_date": "2025-06-30",
      "decision_date": "2026-06-30",
      "effective_date": "2026-07-01",
      "summary": "Rockland Electric's SC7 tariff includes a High Voltage Distribution option for customers with at least 1,000 kW of demand. The BPU originally approved the option in 2008 to facilitate a 25 MW data center in Mahwah and made it generally available for qualifying future high-voltage customers.",
      "investor_takeaway": "New Jersey already has one utility-specific large-load precedent, but SC7 is a high-voltage delivery rate rather than the long-term minimum-demand, collateral, and exit-fee framework used by newer dedicated large-load tariffs.",
      "eligibility": {
        "authorized": {
          "minimum_single_site_mw": 1.0,
          "minimum_aggregate_mw": null,
          "aggregate_radius_miles": null,
          "minimum_service_voltage_kv": null,
          "service_commencement_on_or_after": null,
          "source_id": "source-nj-bpu-rockland-sc7-current-eligibility",
          "as_of_date": "2026-07-01"
        }
      },
      "terms": {
        "authorized": {
          "minimum_contract_years": null,
          "maximum_initial_ramp_years": null,
          "pre_security_satisfaction_minimum_demand_percent": null,
          "firm_minimum_demand_percent_years_1_5": null,
          "firm_minimum_demand_percent_years_6_10": null,
          "interruptible_minimum_demand_percent_years_1_5": null,
          "interruptible_minimum_demand_percent_years_6_10": null,
          "monthly_customer_charge_usd": 2288.12,
          "collateral_requirement": null,
          "exit_fee_requirement": null,
          "direct_upgrade_payment_requirement": null,
          "source_id": "source-nj-bpu-rockland-sc7-current-rates",
          "as_of_date": "2026-07-01"
        }
      },
      "sources": [
        {
          "id": "source-nj-bpu-rockland-sc7-original-order",
          "type": "commission_order",
          "title": "BPU order establishing Rockland SC7 High Voltage Distribution",
          "url": "https://www.nj.gov/bpu/pdf/boardorders/2008/9-12-08-2D.pdf",
          "document_date": "2008-09-12",
          "page": 1,
          "excerpt": "The BPU described a generic high-voltage option for future customers taking service at 69 kV or higher, developed for a 25 MW Mahwah data center.",
          "retrieved_at": "2026-07-14T18:00:00Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        },
        {
          "id": "source-nj-bpu-rockland-sc7-current-eligibility",
          "type": "commission_order",
          "title": "Rockland 2026 base-rate order — current SC7 eligibility",
          "url": "https://www.nj.gov/bpu/pdf/boardorders/2026/20260630/2D%20ORDER%20RECO%20Base%20Rate%20Case.pdf",
          "document_date": "2026-06-30",
          "page": 80,
          "excerpt": "The approved tariff applies High Voltage Distribution service to customers with a minimum demand of 1,000 kW, subject to Company designation and availability where conditions merit.",
          "retrieved_at": "2026-07-14T18:00:00Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        },
        {
          "id": "source-nj-bpu-rockland-sc7-current-rates",
          "type": "commission_order",
          "title": "Rockland 2026 base-rate order — current SC7 rates",
          "url": "https://www.nj.gov/bpu/pdf/boardorders/2026/20260630/2D%20ORDER%20RECO%20Base%20Rate%20Case.pdf",
          "document_date": "2026-06-30",
          "page": 41,
          "excerpt": "Schedule B sets the SC7 High Voltage Distribution monthly customer charge at $2,288.12 including New Jersey sales and use tax, with separate time-of-day demand and usage charges.",
          "retrieved_at": "2026-07-14T18:00:00Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        }
      ],
      "last_verified_at": "2026-07-14T18:00:00Z",
      "review": {
        "status": "approved",
        "notes": "Current status and rates were checked against the 2026 base-rate order. The 2008 order is retained as provenance for the data-center origin and 69-kV design; no modern long-term risk-allocation terms are inferred."
      },
      "display": {
        "utility_name": "Rockland Electric Company",
        "utility_short_name": "Rockland Electric",
        "utility_website_url": "https://www.oru.com/en/about-us/our-service-area/rockland-electric",
        "utility_source_url": "https://investor.conedison.com/",
        "parent_company_name": "Consolidated Edison, Inc.",
        "parent_ticker": "ED",
        "parent_website_url": "https://www.conedison.com/",
        "commission_name": "New Jersey Board of Public Utilities"
      }
    },
    {
      "schema_version": "0.1.0",
      "id": "tariff-pa-puc-ppl-electric-lp-6",
      "state": "PA",
      "commission_id": "commission-pa-puc",
      "docket_number": "R-2025-3057164",
      "related_case_id": "case-pa-puc-r-2025-3057164",
      "title": "PPL Electric Rate Schedule LP-6 large-load interconnections",
      "slug": "ppl-electric-lp-6",
      "tariff_name": "Rate Schedule LP-6",
      "customer_scope": "data_center_and_large_load",
      "utility_id": "utility-ppl-electric",
      "parent_company_id": "company-ppl-corporation",
      "status": "effective",
      "filed_date": "2025-09-30",
      "decision_date": "2026-06-11",
      "effective_date": "2026-07-01",
      "summary": "PPL Electric's LP-6 schedule applies to qualifying large-load customers taking service at 69 kV or above. The schedule establishes long-term service, minimum-demand, security, exit-fee, and directly assigned upgrade-payment requirements.",
      "investor_takeaway": "LP-6 requires qualifying customers to support committed load and upgrade costs through long-term agreements, minimum-demand payments, security, exit fees, and upfront milestone payments.",
      "eligibility": {
        "authorized": {
          "minimum_single_site_mw": 50.0,
          "minimum_aggregate_mw": 75.0,
          "aggregate_radius_miles": 10.0,
          "minimum_service_voltage_kv": 69.0,
          "service_commencement_on_or_after": "2025-10-01",
          "source_id": "source-pa-puc-ppl-lp6-compliance-eligibility",
          "as_of_date": "2026-07-01"
        }
      },
      "terms": {
        "authorized": {
          "minimum_contract_years": 10,
          "maximum_initial_ramp_years": 5,
          "pre_security_satisfaction_minimum_demand_percent": 80.0,
          "firm_minimum_demand_percent_years_1_5": 80.0,
          "firm_minimum_demand_percent_years_6_10": 50.0,
          "interruptible_minimum_demand_percent_years_1_5": 60.0,
          "interruptible_minimum_demand_percent_years_6_10": 30.0,
          "monthly_customer_charge_usd": 999.11,
          "collateral_requirement": "The customer must provide security equal to the rate-base cost of upgrades needed to serve it, using a letter of credit, parent guarantee, or another security instrument acceptable to PPL Electric.",
          "exit_fee_requirement": "The exit fee is the greater of the remaining minimum-load-guarantee obligation during the agreement term or the remaining Rate Base Security Obligation.",
          "direct_upgrade_payment_requirement": "Directly assignable transmission and distribution upgrades require contribution-in-aid-of-construction milestone payments before work is performed.",
          "source_id": "source-pa-puc-ppl-lp6-compliance-terms",
          "as_of_date": "2026-07-01"
        }
      },
      "sources": [
        {
          "id": "source-pa-puc-ppl-lp6-final-order",
          "type": "commission_order",
          "title": "PPL Electric final opinion and order",
          "url": "https://www.puc.pa.gov/pcdocs/1934703.pdf",
          "document_date": "2026-06-11",
          "page": 228,
          "excerpt": "The Commission authorized compliant tariff supplements incorporating the approved settlement terms for service rendered on and after July 1, 2026.",
          "retrieved_at": "2026-07-14T03:06:46Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        },
        {
          "id": "source-pa-puc-ppl-lp6-compliance-eligibility",
          "type": "commission_filing",
          "title": "PPL Electric compliance tariff — LP-6 eligibility",
          "url": "https://www.puc.pa.gov/pcdocs/1937729.pdf",
          "document_date": "2026-06-30",
          "page": 114,
          "excerpt": "LP-6 applies at 69 kV or above to at least 50 MW at one facility or 75 MW in aggregate within a 10-mile radius, subject to the stated exception.",
          "retrieved_at": "2026-07-14T03:06:46Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        },
        {
          "id": "source-pa-puc-ppl-lp6-compliance-terms",
          "type": "commission_filing",
          "title": "PPL Electric compliance tariff — LP-6 service agreement terms",
          "url": "https://www.puc.pa.gov/pcdocs/1937729.pdf",
          "document_date": "2026-06-30",
          "page": 115,
          "excerpt": "The LP-6 agreement requires a minimum 10-year term, load-ramp schedule, security, minimum-demand payments, exit fee, and advance upgrade payments.",
          "retrieved_at": "2026-07-14T03:06:46Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        },
        {
          "id": "source-pa-puc-ppl-lp6-docket",
          "type": "commission_docket",
          "title": "PPL Electric rate case docket",
          "url": "https://www.puc.pa.gov/docket/R-2025-3057164",
          "document_date": null,
          "page": null,
          "excerpt": "The docket shows the June 11 final order and the compliance tariff effective July 1, 2026.",
          "retrieved_at": "2026-07-14T03:06:46Z",
          "evidence_note": null,
          "reviewed_at": null,
          "reviewed_by": null,
          "extraction_method": null,
          "confidence": null,
          "evidence_grade": null
        }
      ],
      "last_verified_at": "2026-07-14T03:06:46Z",
      "review": {
        "status": "approved",
        "notes": "Initial large-load tariff seed reviewed against the PA PUC final order, compliance tariff, and docket. The 50-to-75 MW LP-5 exception remains in the source text and is summarized, not reduced to a separate numeric field."
      },
      "display": {
        "utility_name": "PPL Electric Utilities Corporation",
        "utility_short_name": "PPL Electric",
        "utility_website_url": "https://www.pplelectric.com/",
        "utility_source_url": "https://investors.pplweb.com/sec-filings",
        "parent_company_name": "PPL Corporation",
        "parent_ticker": "PPL",
        "parent_website_url": "https://www.pplweb.com/",
        "commission_name": "Pennsylvania Public Utility Commission"
      }
    }
  ]
}